Mission ~8 min · ~65 min remaining

Prediction: three heights, three decisions

Calculate uy_ref and analytical feasibility before the FE sweep.

Prediction — Three heights, three decisions

With b = 0.05 m, L = 1 m, E = 210 GPa, and F = −1000 N:

I = b·h³/12
uy_ref = F·L³/(3·E·I)
sigma_ref = F·(0.8L)·(h/2)/I   ! interior section
Caseh (m)mesh_h (m)|uy_ref| (mm)σ_ref (MPa)Acceptable (analytical)
10.080.040.74415.0no (> 0.25 mm)
20.100.050.3819.6no
30.120.060.2206.9yes

The analytical prediction already rejects the first two designs. The FE sweep must confirm this with validation_pass and mark only case 3 as feasible.