Demonstration ~10 min · ~31 min remaining

Solve and extract CSV

Anti-rigid-body boundary conditions, SOLVE, RFY at the support, and m11_contact_audit.csv.

Step 4 — Solve, POST1, and CSV

CMSEL,S,bottom_nodes / D,ALL,ALL,0
CMSEL,S,top_nodes
D,ALL,UY,disp / D,ALL,UX,0 / D,ALL,UZ,0
AUTOTS,OFF / KBC,0 / NSUBST,10 / SOLVE

In POST1, sum RFY at the lower support. Write m11_contact_audit.csv with contact_closed, force_error, and n_converged. Measured reference: rfy_close ≈ 5.65 MN, study_passes = 1.